Page 20
Operation
TMC-6700/1000 Series Progressive Scan CCD Digital Color Camera
FIGURE 9. Asynchronous Reset
3.5.2 Asynchronous Reset and Shutter Speed
The TMC-6700/1000 series asynchronous reset operates with internal sync or external HD for phase
locking. When VINIT pulse is applied, it resets the camera’s scanning and purges the CCD. There are
three modes to control the asynchronous reset and shutter speed:
• External VINIT with pulse width control
• Internal shutter speed with fast mode
• Internal shutter speed with slow mode
3.5.2 (a) External Pulse Width Control Mode
To select the external pulse width control mode, set the shutter dial switch to “9.” Apply a VINIT signal
with controlling pulse width, which can be generated from an external event trigger to the camera. The
internal reset pulse will latch to HD. The duration from the first VINIT pulse leading edge to rising
edge, X, controls the shutter speed as follows:
Shutter speed ts = X (1H resolution)
1H = 63.5 µsec.
Min. pulse width = 1H
VINIT
VD
SG (TRANSFER GATE)
DISCHARGE PULSES
VIDEO
ASYNC RESET
Stand-by Image
Async Image