TS-9720EN Series Progressive Scan Shutter Cameras
Page 49
Troubleshooting
(q) Quit
Key in your selection:
Here you should select 7 (Monitor)
Key in your selection: 7
-----------------------------
<< Main Menu->Monitor >>
(1) Line
(2) Async
(3) Async-setting
(m) Back to main menu
(q) Quit
Key in your selection:
Here you should select 1 (Line)
Then you will get a display like this:
Port Type IP1 IP2 IP3 IP4
01 TCP Server 10.0.0.101 10.0.0.102 Listen Listen
02 TCP Server Listen
5. Press “q” to cancel. This will bring up a screen displaying who is connected to the Moxa NPort
device. If you have reached the limit of numbers of simultaneous connections, this information will
explain why additional users cannot connect to the Moxa device.
7.7 Problem 7: IO Board Communication Error
The IO board has a temperature sensor, a housing-open sensor, and other event sensors. When these
events occur, the IO board sends a warning to the EN camera through the 9600 bps UART. If you are
not using an IO board and a 26-pin HD-Sub cable, then you will have an IO board communication error
message. In this situation, you can simply ignore this message.
If you are using an IO board and a 26-pin HD-Sub cable and still see an IO board communication error,
then the baud rate of the EN camera may not match that of the IO board communication UART. In this
situation, you need to set the EN IO board rate register to 9600 bps, so that it matches the IO board
UART factory default (9600bps).