TS-9720EN Series Progressive Scan Shutter Cameras
3.5 Static IP Address Assignment
The factory default IP assignment is static IP= 10.0.0.65. The user must change the IP address of the
camera. There are four methods to change the static IP address: EN setup software, Telnet,serial
terminal using the debug RS-232 serial/power cable, and BIOS/Monitor using the debug RS-232 serial/
power cable.
The first two options, EN setup software, and Telnet, require that the network settings of the EN camera
such as IP address and Subnet Mask be known, while the last two options do not. If Ethernet is not
available, then the last two options will be useful.
The EN setup software is the easiest way to change IP address. In the “Properties” window, change the
network setting registers. After changing these registers, reboot the camera. The new setting appears at
the next power-up.
Telnet
If you know the current IP address of the camera, you can telnet directly to the EN camera. Login
as User name = root, Password = JAI PULNiX. If you want to assign a new IP address temporarily,
you can use the “ifconfig” utility. If you want to assign a new IP address permanently, you can use
the “test_libcamera” utility (See Section 3.6.3, “RS-232 PowerPC Debug Port,” on page 24).
Serial terminal using the debug RS-232 serial/power cable.
This is exactly the same as the previous “Telnet” solution, except that you do not need an Ethernet
connection. If Ethernet is down, or if the IP of the camera is unknown, this method is useful. You
can use “ifconfig” or “test_libcamera” utility to assign new IP address temporarily or permanently
(See Section 3.6.3, “RS-232 PowerPC Debug Port,” on page 24).
BIOS/monitor using Debug RS-232 Serial/Power cable.
The BIOS/monitor is an even lower level of software running underneath of OS and application
code. By using the BIOS/monitor, you can assign a new IP address permanently. See Section 3.6.3,
“RS-232 PowerPC Debug Port,” on page 24 for detailed operation.
3.5.1 DHCP Client
Make sure that you have a DHCP server in your network.
Change the “Static/Dynamic IP Address Allocation” register from “Static” to “Dynamic.”