TS-9720EN Series Progressive Scan Shutter Cameras
Page 29
Uploading the Firmware
4 Uploading the Firmware
There are five pieces of firmware inside the EN camera that you can upload over the Ethernet. They are:
EN_APP: top-level application software.
OS_Image: Linux OS image and basic tile system
Lib/drV: library and driver file package
FPGA Bitfile: FPGA firmware
H8: H8 firmware. H8 is responsible for serial communication to the CCD
camera module and Gamma LUT.
4.1 To Verify Version Numbers for all Firmware
You can verify the version numbers of all firmware by using the RS-232 PPC debug serial port/telnet or
the EN setup software. Both methods are explained below.
4.1.1 RS-232 PPC Debug Serial Port/Telnet
To verify the version numbers of all firmware with the RS-232 PPC debug serial port/telnet, login to EN
camera as ROOT with the following user name and password:
user name: root
password: JAIPULNiX
Type “en-v” to see the version numbers for all firmware currently running.
Ex: #en-v > version.txt
#more version.txt
Welcome to JAI-PULNiX EN Camera
EN version : 050812A0
OS version : 050810A0
Lib/drv version : 050812A0
FPGA version : 050805C0
4.1.2 EN Setup Software
To verify version numbers for all firmware using the EN setup software, follow the steps below:
1. Start the EN setup software.
2. Click the “Properties” button.
3. Search for cameras in the network.
4. Left-mouse click on the camera you want.
5. Find the version numbers.
4.2 Updating the EN Application Software
The EN setup software is used to update the EN application software. The method is described below.