3.1.2 Internal Shutter Speed Control
Note: In order to enable Reset-Restart sync pulse, F2 function selection must be ON. Normal
external VD is detected automatically when F2 is OFF. In this mode, if there is no external
VD, internal VD is automatically generated.
3.1.3 Field and Frame Modes
The standard factory setting for the TM-75/76 camera is FRAME MODE. The field and frame
integration mode is selectable using the #2 switch of the mode switch inside the camera. The frame
integration is used to separate all CCD pixels. The exposure of Odd and Even fields generates the full
frame image shown in Figure 3, “Field/Frame Diagram,” on page 10.
TABLE 2. Shutter Speed Control and Function
Mode SW Rotary SW Shutter Speed Trigger
F1 NO. Second H lines
OFF 0 No shutter
OFF 1 1/60 261.5
OFF 2 1/100 157.5
OFF 3 1/120 130.5
OFF 4 1/250 62.5
OFF 5 1/500 31.5
OFF 6 1/1,000 15.5
OFF 7 1/1,500 10.5
OFF 8 1/2,000 7.5
OFF 9 1/2,800 5.5
OFF A 1/3,500 4.5
OFF B 1/4,500 3.5
OFF C 1/6,000 2.5
OFF D 1/10,000 1.5
OFF E 1/29,000 0.5
ON D
Snapshot
a
a. Snapshot mode is similar to Donpisha mode.
Variable >0 Positive
ON E RR Position Variable >0.5 Positive
ON F RR Width Variable >2.5 Positive