5.Asynchronous Reset and Asynchronous
Shutter
By supplying VINIT pulse on pin #6, the camera can be reset
asynchronously. In this mode, when VINIT is kept high, it keeps
discharging the CCD and outputs the field video signal upon
the negative going edge.The output stays continuous during
VINIT low.The first field output is always Odd.
Async Shutter with External Shutter Timing control
6. Reset-Restart Mode
Rather than using VINIT as async reset, the camera can be
reset using EXT.VD. In this mode, camera needs multiple VD
pulses to output valid images depending on whether it is set
to Field or Frame mode. Usually, the first field (field mode) or
first frame (frame mode) are garbage because of previous sig-
nal residuals prior to reset.A frame grabber has to know
which frame or field to capture. External HD must be applied
for this operation.
7. Reset-Restart with Electronic Shutter
The shutter speed or exposure can be controlled with
external pulse width control in this mode. In combination with
Reset-restart pulse (EXT.VD), the camera can be externally
controlled for the image-capture timing as well as the expo-
sure time.
This is an excellent application for capturing multiple images
(two fields of images) of indexing objects under various light-
ing or brightness conditions.When Frame mode is selected,
the full vertical resolution is achieved even using an electronic
shutter by taking two fields of shutter images.
8. Integration Mode
When integration control is low, the CCD imager keeps
integrating and when the signal returns to high, it enables the
charge transfer for video output.This mode integrates longer
than one field and with strobe light application, it can capture
randomly strobed images during the integration. It also
increases the exposure time to enhance low light viewing.
www.pulnix.com
TM-250/260 High-Resolution CCD Camera
12P-02S Interface Cable (optional)
Pin# Lead Color Function Pin Configuration
1 Gray GND
2 Yellow +12VDC
3 Red coax shield GND
4 Red coax Video
5 Orange coax shield GND
6 Orange coax VINIT
7 Black coax VD Input
8 White coax shield GND
9 White coax HD Input
10 Brown N/C
11 Blue N/C
12 Black coax shield GND
EXT. HD for PLL(Relationship with HD and Reset-Restart VD affects Odd or Even field output)