OPERATION
TM-1300 Progressive Scanning High Resolution Camera Page 11
3 OPERATION
3.1 Modes of Operation
The TM-1300 is designed to accommodate a high resolution, on-line inspection reset mechanism with
full frame shutter. It accepts external horizontal sync (HD, TTL Levels) to lock the camera and VINIT
pulse for resetting the camera asynchronously. The shutter speed can be controlled by either RS-232
computer commands or internal shutter speed control with a 10-position dial switch on the back panel.
3.1.1 Shutter Control Switch
The TM-1300's asynchronous reset is flexible and takes external HD for phase locking. Applying a
VINIT pulse resets the camera's scanning and purging of the CCD. Do not supply VD if the
asynchronous reset is used. Instead, use HD to synchronize the camera to the external device.
When the async reset pulse (VINIT) is applied to High state (+5V)
with the dial switch set from1 to 9, the TM-1300 asynchronous
camera discharges the photo charges into the substrate drain
although the camera is still running on its sync timing and only
outputs captured video. When the negative going reset pulse is
applied, the camera will latch the falling edge to its next horizontal
drive and will immediately reset the vertical sync timing. The
maximum delay is 80.645µsec. (1H). Then the camera will start
integrating for the period of shutter control set by either computer
control or internal shutter control. Therefore the horizontal phase
will not be interrupted. The TM-1300 asynchronous camera will output one full frame of shuttered
video after reset.
TABLE 1. Shutter Control Settings
Set Manual Shutter Mode Async Reset Mode
0 No Shutter (1/12) No Shutter (1/12)
1 1/50 1.5H 1/39,000
2 1/100 2.5H 1/9,500
3 1/200 4.5H 1/5,500
4 1/400 8.5H 1/3,000
5 1/1,500 16.5H 1/1,500
6 1/3,000 32.5H 1/400
7 1/5,500 64.5H 1/200
8 1/10,000 64.5H 1/245
9 1/39,000 256.5H 1/50