Pulnix TS-9720EN Series Bedienerhandbuch Seite 1

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Brückenkameras Pulnix TS-9720EN Series herunter. Pulnix TS-9720EN Series Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - VIS 300/400 EN Setup Software

10407Rev. AImaging ProductsOperation ManualVIS 300/400 EN Setup Software

Seite 2

Page xVIS 300/400 EN Setup SoftwareFIGURE 50. Manual Exposure Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 3 - Certifications

November 8, 2006VIS 300/400 EN Setup SoftwareJAI PULNiX Intelligent Transportation SystemsVehicle Imaging System 300 and 400(VIS 300/400)EN Setup Soft

Seite 4 - WARNING

Page 2Document OverviewVIS 300/400 EN Setup Software1 Document OverviewThis document describes the EN Setup program for the VIS CAM 300/400 Vehicle Im

Seite 5 - Table of Contents

Page 3Installation and OperationVIS 300/400 EN Setup Software2 Installation and Operation2.1 InstallationTo install the program follow the EN Setup I

Seite 6 - Appendix

Page 4Installation and OperationVIS 300/400 EN Setup SoftwareThe last User name is automatically filled in the next time the program is started.Tip I

Seite 7 - Page vii

Page 5Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 4. EN Camera File Menu Bar Options2.4.3 (a) File=>Open Camera This command o

Seite 8 - Page viii

Page 6Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 6. Tools Menu 2.4.4 (b) View Error Log The View Error Log command opens a new w

Seite 9 - List of Figures

Page 7Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 8. Camera Properties Window

Seite 10

Page 8Installation and OperationVIS 300/400 EN Setup Software2.5.1 Camera Property Menus Using the commands on the File menu the camera properties can

Seite 11 - Operation Manual

Page 9Installation and OperationVIS 300/400 EN Setup Software2.5.1 (c) File=>Page Setup The Page Setup command opens a dialog box for selecting

Seite 13 - 2 Installation and Operation

Page 10Installation and OperationVIS 300/400 EN Setup Software2.5.1 (e) File=>Print sends the print job to the printer 2.5.1 (f) File=>Exi

Seite 14 - File Menu Bar

Page 11Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 13. Camera Property Tree View

Seite 15 - 2.4.4 Tools Menu Bar

Page 12Installation and OperationVIS 300/400 EN Setup Software2.5.3 (a) Context menusRight-side clicking the mouse on the camera-tree side of the C

Seite 16 - 2.5 Camera Properties

Page 13Installation and OperationVIS 300/400 EN Setup Software2.5.4 => Advanced Settings Sub MenusThis command opens up a sub-menu with all availab

Seite 17

Page 14Installation and OperationVIS 300/400 EN Setup Softwareneed to be setup then please use the Advanced Settings=>Copy Settings from Camera and

Seite 18 - 2.5.1 Camera Property Menus

Page 15Installation and OperationVIS 300/400 EN Setup Software2.5.6 Property gridThe listings in the property grid of the CAMERA PROPERTIES can be sho

Seite 19

Page 16Installation and OperationVIS 300/400 EN Setup SoftwareWhen a category is maximized the values are shown as in Figure 18 on page 16. Some value

Seite 20 - 2.5.3 Tree view

Page 17Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 19. Property Description in the Bottom of the WindowEditing the value field can b

Seite 21

Page 18Installation and OperationVIS 300/400 EN Setup Software2.6 Video WindowThe VIDEO WINDOW is shown in Figure 23 on page 18. The left side of the

Seite 22

Page 19Installation and OperationVIS 300/400 EN Setup Software2.6.1 Video Menu MenusFIGURE 24. Video Window File Menu Bar2.6.1 (a) File=>Open… T

Seite 23

Page iiiVIS 300/400 EN Setup SoftwareNoticeThe material contained in this manual consists of information that is proprietary to JAI PULNiX, Inc., and

Seite 24

Page 20Installation and OperationVIS 300/400 EN Setup Software2.6.2 Edit Menu MenusFIGURE 25. Video Window Edit Menu Bar2.6.2 (a) Edit=>Copy Thi

Seite 25 - 2.5.6 Property grid

Page 21Installation and OperationVIS 300/400 EN Setup Software2.6.3 (d) View=>Use TCP/IP This command selects if the images are transferred from

Seite 26

Page 22Installation and OperationVIS 300/400 EN Setup Software3. Timestamp (UTC) 10:56:34.8974. TST (test) image captured from the “test-channel” (UDP

Seite 27

Page 23Installation and OperationVIS 300/400 EN Setup Software2.6.4 (b) Capture=>Capture folder … This command selects the folder to where the c

Seite 28 - 2.6 Video Window

Page 24Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 32. Video Window Tree View Menus2.6.5 (b) =>Search for cameras This command

Seite 29 - 2.6.1 Video Menu Menus

Page 25Installation and OperationVIS 300/400 EN Setup Software2.6.5 (f) =>Image Processing This command opens a new window that displays the ima

Seite 30 - 2.6.3 View Menu Menus

Page 26Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 33. Video Window Context Menus2.6.6 (b) =>Unselect Camera This command clea

Seite 31 - 2.6.4 Capture Menu Menus

Page 27Installation and OperationVIS 300/400 EN Setup Software2.6.6 (g) Zoom Video ImageIt is possible to zoom in on the images displayed by draggi

Seite 32

Page 28Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 35. Display ModesThe various display modes remember the trigger modes that was se

Seite 33 - 2.6.5 Tree view

Page 29Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 36. Setup Tools MenuThe setup tools can be configured using the Settings Dialog,

Seite 34

Page ivVIS 300/400 EN Setup SoftwareWARNING Changes or modifications to this unit not expressly approved by the party responsible for FCC compliance c

Seite 35 - 2.6.6 Video Image

Page 30Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 37. Camera Roll Bar Tilt LineThe Tilt Line inserts a horizontal line with two ver

Seite 36

Page 31Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 38. Camera Tilt LineTilt Line data

Seite 37 - FIGURE 34. Tool Bar

Page 32Installation and OperationVIS 300/400 EN Setup Software Focus Bar The Focus Bar is a horizontal line with same length as the distance between t

Seite 38

Page 33Installation and OperationVIS 300/400 EN Setup Software Measuring Box The Measuring Box is used to measure the dimension of e.g. the license pl

Seite 39

Page 34Installation and OperationVIS 300/400 EN Setup Software2.6.7 (c) Trigger ModesTrigger modes can be selected using the Tool bar as shown in F

Seite 40

Page 35Installation and OperationVIS 300/400 EN Setup SoftwareThe default trigger mode is Last and the latest UTC labelled image can always be transfe

Seite 41

Page 36Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 43. Video Window Settings Dialog Box2.6.8 Status BarThe Status Bar shows tool val

Seite 42

Page 37Installation and OperationVIS 300/400 EN Setup Software2.6.9 Focus Bar WaveformThe FOCUS BAR WAVEFORM window is opened when the Focus Bar is se

Seite 43

Page 38Installation and OperationVIS 300/400 EN Setup SoftwareThe column height can vary between 0 and 100%. FIGURE 46. Focus Bar Waveform Menus2.6.9

Seite 44

Page 39Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 47. Waveform Screen Commands. 2.6.10 Edit=>Copy This command copies the Graph

Seite 45

Table of Contents1 Document Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Installation and Operation . . . . . . .

Seite 46 - 2.6.8 Status Bar

Page 40Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 48. Image Properties Context MenuIf the “Use TCP/IP” option is selected (see Sect

Seite 47 - 2.6.9 Focus Bar Waveform

Page 41Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 49. Image Properties with the TCP/IP option selected

Seite 48

Page 42Installation and OperationVIS 300/400 EN Setup SoftwareThe image tags are generated inside the camera and therefore contain information such as

Seite 49 - 2.6.10 Edit=>Copy

Page 43Installation and OperationVIS 300/400 EN Setup Software2.6.12 (b) Gain Value:The Gain Value setting directly control the gain applied to ima

Seite 50

Page 44Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 52. Vehicle Detector SettingsIn the Property Grid control all values can be manua

Seite 51

Page 45Installation and OperationVIS 300/400 EN Setup SoftwareThe Laser Setup dialog will be used to setup the Laser Vehicle Detector connected to the

Seite 52 - 2.6.12 Manual Exposure Window

Page 46Installation and OperationVIS 300/400 EN Setup Software2.6.14 (a) Laser Setup WizardThe easiest way to configure a laser vehicle detector is

Seite 53 - 2.6.14 Laser Setup Window

Page 47Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 55. Laser Wizard data collectionData collection will start automatically but need

Seite 54

Page 48Installation and OperationVIS 300/400 EN Setup SoftwareFIGURE 56. Successful data collectionIt is now possible to specify two offset values dir

Seite 55

Page 49Installation and OperationVIS 300/400 EN Setup SoftwarePress Next after the offset values are determined. Next specify the Filter Size used by

Seite 56

Page viAppendixVIS 300/400 EN Setup Software2.5.5 =>Refresh Properties (toggle function) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Seite 57

Page 50Installation and OperationVIS 300/400 EN Setup SoftwareNext specify the Hysteresis Count used by the laser. In order for the laser to generate

Seite 58

Page 51Installation and OperationVIS 300/400 EN Setup SoftwareThe results generated by the laser will be displayed. Press Next to finish the Wizard.Cl

Seite 59

Page 52Installation and OperationVIS 300/400 EN Setup Software2.7 Error Log WindowThe ERROR LOG window is activated from the EN CAMERA SETUP windows T

Seite 60

Page 53 ConfigurationVIS 300/400 EN Setup Software3 Configuration3.1 User administrationThe User Administration menu is found in the EN CAMERA SETUP t

Seite 61

Page 54 ConfigurationVIS 300/400 EN Setup Software3.2 Firmware updateIt is possible to update the firmware inside the cameras via the context menu des

Seite 62 - 2.7 Error Log Window

Page 55 ConfigurationVIS 300/400 EN Setup Software4. Library/DriverLow Level Firmware used by the EN Application to communicate with the hard-ware. Th

Seite 63 - 3 Configuration

Page 56 ConfigurationVIS 300/400 EN Setup Software3.3 Configure Storage MemoryThe internal image storage memory can be individually configured for eac

Seite 64 - 3.2 Firmware update

Page 57AppendixVIS 300/400 EN Setup SoftwareAppendix A: PC Minimum SpecificationsSoftware:• Windows XP Service Pack 2• Dot NET framework 2.0Hardware:•

Seite 65 - Configuration

Page 58AppendixVIS 300/400 EN Setup SoftwareAppendix B: Resolving IP-address problemsWhen the automatic device discovery searches for cameras on the n

Seite 66 - 3.3 Configure Storage Memory

Page 59AppendixVIS 300/400 EN Setup SoftwareFIGURE 71. Set New IP Address WindowTip Double-click the camera in the list that you want to set a new IP

Seite 67

Page viiAppendixVIS 300/400 EN Setup Software2.6.11 Image Properties Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 68

Page 60 ConfigurationVIS 300/400 EN Setup Software

Seite 69

JAI PULNiX, Inc.625 River Oaks ParkwaySan Jose, CA 95134Tel: 408-383-0300Tel: 800-445-5444Fax: 408-383-0301www.jaipulnix.comImaging Products10407Email

Seite 71 - Imaging Products

Page viiiVIS 300/400 EN Setup Software

Seite 72

Page ixVIS 300/400 EN Setup SoftwareList of FiguresFIGURE 1. EN Setup Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Kommentare zu diesen Handbüchern

Keine Kommentare