INSTALLATION
Page 8 TM-6703 Progressive Scan Double Speed Shutter Camera
2.2.7 Auto Iris Lens Setup
Auto-iris lenses with full video input (1 Vpp) can be used with the PULNiX TM-6703, although this
camera model does not come equipped with auto-iris output.
Note: Make sure that the power is removed from the camera before connecting or disconnecting
the auto-iris lens. There is a small chance that damage could occur to the auto-iris lens by
plugging or unplugging it while the camera is powered up.
To install the auto-iris lens in a PULNiX camera for which the auto-iris output is not supplied, wire the
signal (video) on the lens into the terminal 1 Vp to peak video output on the camera (pin 4 of 12 pin
connector).
Point the camera at a light area and then quickly towards a darker area. If everything is working
properly, the iris should adjust for the light change.
2.2.8 Non-Interlace Black & White Monitors
The PULNiX PVM-942 / 1242 non-interlace black and white monitor, or an equivalent model, can be
used to display the TM-6703’s various display modes. In standard operation, including RS-170
interlace, 60 Hz non-interlace, 30 Hz non-interlace and 120 Hz non-interlace (two-row scanning mode),
the display is normal. In the partial scanning mode, the vertical extends to fill the monitor screen and the
images will be distorted vertically.