Operation Mode
TM-250 Miniature CCD Camera
5.2.5 Double Pulse Integration Mode
Double Pulse Integration mode enables exposure times to be longer than one field. It also works for
strobe applications. The camera operates in the same way as it does in Asynchronous Strobe Shutter
mode. The transfer occurs only at one field in Field Accumulation mode, or at two fields in Frame
Accumulation mode after the leading edge of VINIT pulse is detected. Discharge does not occur in this
mode so that the previous VINIT clears the photo accumulation, as in Cyclic No Shutter. Sync signal is
continuous when F2 switch is up (ON). Sync is available in the two fields (frame mode) and in the one
field (field mode) right after VINIT when the F2 switch is down (OFF).
FIGURE 18. Double Pulse Integration Mode
5.2.6 Pulse Width Integration Mode
Pulse width mode integration enables exposure time to be longer than one field and also works for
strobe application. The camera operates in the same way as it does in Async Pulse Width Mode Shutter.
When VINIT is high, train of discharge pulse occurs. When the falling edge of VINIT pulse is detected,
the discharge stops and photo-charge accumulation starts. The rising edge of VINIT reset camera and
transfer happens at 11th line with TM-250 and at 16th line with TM-260. The transfer occurs only at
one field in field accumulation mode or at two fields in frame accumulation mode. SYNC signal is
continuous when F2 switch is Up (ON). SYNC is available only in the two fields (frame mode) and in
the one field (field mode) right after VINIT, when the F2 switch is down (OFF).
TABLE 12. Double Pulse Integration Mode
F1
OFF
ASY
CYC
S3
0
S2
0
S1
0
S0
0
TRIGGER
Polarity
Up Up Up Up Up Down Negative
F2 Up: SYNC signal is continuous.
F2 Down: SYNC signal is available in the two fields (Frame
mode) and in one field (Field mode) right after VINIT.
Reset Reset
VINIT
Video Out
Transfer
Strobe
Exposure
(Integration)
Internal VD