Operation
TM-250 Miniature CCD Camera
3.2.1 Timing
FIGURE 4. TM-250 Timing Chart
3.2.2 Interfacing to Frame Grabbers
The TM-250 camera can be connected to a frame grabber using either the 12-pin connector or the BNC
connector on the rear panel of the camera.
3.3 Operating Modes
Besides normal operation, the TM-250 supports the following versatile operations that can be selected
by the DIP switch on the rear panel of the camera:
Standard Interlace Mode
Field integration Mode
Frame Integration Mode
External Sync Mode
Non-interlace Mode
Cyclic (Continuous) Shutter Mode
Asynchronous Reset and Asynchronous Shutter
Image sensing period
Optical
black period
Dummy
H register
H register
stop period
Optical
black period
CCD photo sensors
allocation
CCD output
signal
Effective picture
period
HD
6.36µSec
91
40 77 22 3
819
768
40
154
H BLK 10.76µSec
21
1.47µSec
70
H SYNC
4.89µSec
Composite video
output
B1
B2
B3
1
2
3
4
5
6
7
8
9
10
757
758
759
760
761
762
763
764
765
766
767
768
B1
B40
B1
D1
D22
910
63.56µSec (1 horizontal line)
B40
CBRK