Pulnix TM-250 Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
Mode Contr
Mode Contr
ol Switches
ol Switches
Exter
Exter
nal Synchr
nal Synchr
onization
onization
Mode Control Switch Up/Down Switch
0 Normal mode
1 Gain control (A/B) up/down - increase/decrease gain of Ch. A & Ch. B
2 Gain (A/B) fine tune up/down - increase/decrease gain of Ch. A, while decrease/increase gain of Ch. B, at 5:1 ratio
3 ChA Vref control up/down - increase/decrease A/D voltage reference of Ch. A
4 ChB Vref control up/down - increase/decrease A/D voltage reference of Ch. B
5 Gain selection up: 9dB down: 12dB
6 Gain selection up: 18dB down: 22dB
7 Clock selection up: 120Hz down: 60Hz
8 Async / Manual shutter up: Manual down: Async
9 Factory set recall up/down: recall only
A Power up (recall or save) up: recall down: save
B-C User page storage up: recall down: save
(store user settings)
D Direct Shutter up/down - increase/decrease manual shutter speed
E Partial scan up: 100 lines down: normal scan (or binning)
F Partial scan up: normal scan down: 200 lines
Shutter Control Switch
Manual Shutter Async Reset
0 no shutter 1/120 normal 1/120
1 1/250 128H 1H 1/32,000
2 1/500 64H 2H 1/16,000
3 1/1,000 32H 3H 1/12,000
4 1/2,000 16H 4H 1/8,000
5 1/4,000 8H 8H 1/4,000
6 1/8,000 4H 16H 1/2,000
7 1/12,000 3H 32H 1/1,000
8 1/16,000 2H 64H 1/500
9 1/32,000 1H Shutter determined
by pulse width (P.W.C.)
Async Reset Mode: Mode 0: normal mode; Mode 1-4: fast mode;
Mode 5-8: slow mode; Mode 9: pulse width mode. At modes 1-9
the camera is at standby only, black video is output. One frame
image will be output upon receiving an async reset pulse.
Electr
Electr
onic Shutter
onic Shutter
The TM-6710 has a substrate drain type shutter
mechanism which produces a superb picture at various
speeds without smearing. The built-in manual shutter
speed control selects the electronic shutter rate of
1/125, 1/250, 1/500, 1/1,000, 1/2,000, 1/4,000, 1/8,000,
1/16,000, or 1/32,000 sec. All shutter speeds are
applied to partial scan, except slow speed at partial
scanning. Progressive scanning allows a full 484 lines
of vertical resolution per single shutter, unlike a
conventional CCD camera at only 244 lines per shutter.
Partial Scanning
By setting the mode switch on the back plate and sending
the RS-232 command, the TM-6710 can have partial
scanning of 200 and100 lines (full resolution at narrower
field of view and faster frame rate).
Switch selection
Normal mode: F UP 120 Hz progressive scan
200 line scan: F DWN 240 Hz progressive scan
100 line scan: E UP 350 Hz progressive scan
(Special option: 2-row binning at 240 lines, 240 Hz)
VINIT
VD
SG (TRANSFER GATE)
DISCHARGE PULSES
VIDEO
SHUTTER
VIDEO
NON-INTERLACE OUTPUT
ASYNC RESET
VIDEO
POWER
SHUTTER
0
1
2
3
4
5
6
7
8
9
DWN
UP
MODE
DIGITAL
1
0
2
3
4
5
6
7
8
9
A
B
C
D
E
The TM-6710 can accept external HD and VD for phase locking. The
internal PLL will accept external HD and lock with the CCDs
horizontal drive (H
D). The CCD HD frequency is half of the analog
video output H
D.
Example: Ext. HD = 30.49 kHz; VD will be 120 Hz and Master
Clock will be 50.90 mHz.
The internal sync generator will accept external V
D to generate internal
VD. The external VD frequency should be ±5% of the frame rate.
1µF
C1
R1
Ext HD
(or Ext VD)
4.7k
OUTSIDE
CAMERA
INSIDE CAMERA
External Sync Input Schematic
Rear Panel
Ext. HD = HD Output Frequency
Frequency.
__________________
2
(input sync changed automatically)